Electrical Safety Analyzers are used for a staggering number of applications, so why be stuck with one model available. Our five base models allow you to pick what you need and save some money at the same time. Need communications? RS232 is now available on ALL models. Doing International testing? Our INTL versions work worldwide.

Safety Analyzer – Australian – 10 Lead w/ Sim

SA-2010S-AUS

The BC Biomedical Model SA-2010S Series is a microprocessor-based Electrical Safety Analyzer with a built in Patient Simulator. It allows for a multitude of tests to be performed on a device using the same unit and lead connections. It provides a full Electrical Safety Analyzer, ECG Simulation with four waveforms with constant QRS duration and six machine performance testing waveforms. There is patient lead testing for 10 inputs.

Read more
  • Led status indicators
  • Audio feedback
  • Touch control keys – no knobs
  • 10 universal patient lead inputs 
  • High impact plastic case
  • Line voltage measurement 
  • Device under test current measurement
  • Earth / ground lead resistance
  • Earth / ground leakage current 
  • Enclosure / chassis leakage current
  • External resistance 
  • External leakage current 
  • Source receptacle wiring integrity monitor 
  • True RMS measurements 
  • AAMI ES1-1993 or IEC 601 selectable test loads 
  • 85 to 265 VAC operation 
  • Full 20 amp rating
  • Self test points 
  • Externally replaceable ground fuse 
  • Automatic load reversal delay 
  • Patient lead to lead leakage current 
  • Patient lead to earth / ground leakage current 
  • Patient isolation leakage current 
  • External isolation leakage current Patient Simulator Capabilities: 
  • Sine: 10, 60 AND 100 HZ 
  • ECG: 30, 60, 120 AND 240 BPM 
  • Square: 0.125 AND 2.0 HZ 
  • Triangle: 2 HZ 
  • High level output (1 V p-p) 
  • Amplitude accuracy: +/- 2%
  • Frequency accuracy: +/- 0.5% SA-2010S-R: 
  • RS-232 Serial Communications

Safety Analyzer – Australian – 10 Patient Leads

SA-2010-AUS

The BC Biomedical Model SA-2000 Series is a microprocessor-based Electrical Safety Analyzer family. All three models provide the same basic functions. The SA-2005 adds patient lead testing for five inputs. The SA-2010 adds Patient Lead testing for 10 inputs. The following are highlights of some of the main features:

Read more
  • Line voltage measurement 
  • Device under test current measurement
  • Earth/ground lead resistance 
  • Earth/ground leakage current 
  • Enclosure/chassis leakage current
  • External resistance 
  • External leakage current 
  • Source receptacle wiring integrity monitor 
  • True RMS measurements 
  • AAMI ES1-1993 or IEC 601 selectable test loads 
  • 85 to 265 VAC operation
  • Full 20 Amp rating
  • Touch control keys – no knobs
  • Led status indicators 
  • Audio feedback 
  • Self test points
  • Externally replaceable ground fuse 
  • Automatic load reversal delay 
  • Patient lead to lead leakage current 
  • Patient lead to earth/ground leakage current 
  • Patient isolation leakage current 
  • External isolation leakage current 
  • 10 universal patient lead inputs
  • RS-232 Serial Communications

Safety Analyzer – Australian – 5 Patient Leads

SA-2005-AUS

The BC Biomedical model The SA-2005 is a microprocessor-based Electrical Safety Analyzer family. All three models provide the same basic functions. The SA-2005 adds patient lead testing for five inputs.

Read more
  • Line voltage measurement 
  • Device under test current measurement
  • Earth/ground lead resistance 
  • Earth/ground leakage current 
  • Enclosure/chassis leakage current
  • External resistance 
  • External leakage current 
  • Source receptacle wiring integrity monitor 
  • True RMS measurements
  • AAMI ES1-1993 or IEC 601 selectable test loads 
  • 85 to 265 VAC operation 
  • Full 20 Amp rating 
  • Touch control keys – no knobs 
  • Led status indicators 
  • Audio feedback
  • Self test points
  • Externally replaceable ground fuse 
  • Automatic load reversal delay 
  • Patient lead to lead leakage current 
  • Patient lead to earth/ground leakage current 
  • Patient isolation leakage current 
  • External isolation leakage current 
  • 5 universal patient lead inputs
  • RS-232 Serial Communications

Safety Analyzer – Australian – Base Model

SA-2001-AUS

The BC Biomedical model SA-2001 is a microprocessor-based Electrical Safety Analyzer. All three models provide the same basic functions.

Read more
  • Line voltage measurement 
  • Device under test current measurement
  • Earth/ground lead resistance
  • Earth/ground leakage current 
  • Enclosure/chassis leakage current
  • External resistance 
  • External leakage current 
  • Source receptacle wiring integrity monitor 
  • True RMS measurements 
  • AAMI ES1-1993 or IEC 601 selectable test loads 
  • 85 to 265 VAC operation 
  • Full 20 Amp rating 
  • Touch control keys – no knobs 
  • Led status indicators 
  • Audio feedback 
  • Self test points
  • Externally replaceable ground fuse 
  • Automatic load reversal delay
  • RS-232 Serial Communications

Safety Analyzer – Australian – Lite Model

SA-2000-AUS

The BC Biomedical model SA-2000 is a microprocessor-based Electrical Safety Analyzer.

Read more

It can also be used by customers who desire to test their ESU generators in the exact same way the medical device manufacturers do. BC Biomedical’s DFA ESU Analyzers are the only analyzers with a 1% reading level of accuracy

Calibration quality analyzers use external precision non-inductive test loads and wide band current transformer. Standard model is compatible with all legacy generators with continuous output waveforms, and with the latest technology generators such as the Covidien Force Triad, Ligasure Blood Vessel Dealing generator, etc. The standard model is NOT compatible with generators that produce pulsed output waveforms.

This device requires a Pearson Coil and External Resistors (not included).

  • A BC20-00230 Pearson CT 4100 1:1 OR a BC20-00231 Pearson CT 411 0.1:1 (most commonly used) is needed. You will also need to purchase one or more Precision Resistors depending on the ESU platform you are testing.
  • A CQM-2000 is helpful if you do not have another means of testing CQM/REM/ARM.
  • True RMS readings using DFA® Technology
  • 1% measurement accuracy • Uses external current transformer & loads 
  • mV, mV Peak, mA, crest factor & wattage displays
  • Waveform capture, storage, display & download 
  • Graphic display with bright white backlight 
  • Price Includes: Universal Power Supply, Soft Carrying Case, RS-232 & USB Communication Cables, BNC to BNC Cable (3-foot) for current 
  • Transformer connection, PC utility software

Safety Analyzer – Full PC Automation Version

SA-2500

The SA-2500 is a Microprocessor based Electrical Safety Analyzer.

There are 2 Modes of operation, Manual and Remote. The Manual mode allows most basic testing functions to be stepped through one at a time. With the Remote mode, measurements are controlled via a PC. The user has the possibility to integrate all measurements into the individual operator interface at the PC and to define test sequences.

Read more

International Adapter Plug-BC20-20400 (If International Power Cord is Selected)

Power Cord Included

Kelvin Coiled Chassis Cable, BC20-20150 Plug-on alligator clip, BC20-20152

CD-ROM with remote control software

USB Cable, BC20-41352

Large Soft Sided Case Carrying, BC20-30108

NIST Certificate and Operator Manual

Safety Analyzer Add-On – 1 Amp Current Source

CS-2000

The model CS-2000 is a one amp current source for testing the ground continuity in equipment. This device facilitates testing to IEC601 requirements, where a one amp source current is required. This device interfaces directly with BC Biomedical SA series of Safety Analyzers as well as the Dale 544D, 544D LITE and 601/601E Safety Analyzers.

Read more
  • Facilitates testing to iec601 requirements 
  • Interfaces directly to BC Biomedical SA-2000 Series of safety analyzers 
  • Interfaces to Dale 544D, 544D LITE, 601 and 601E safety Analyzers 
  • Universal power supply (85 – 265 VAC, 50/60HZ) 
  • 1 amp current source for resistance measurements 
  • No protruding push buttons • Light touch key used to operate 
  • Small, compact size 
  • CS-2000U for USA market
  • CS-2000E for Europe (schuko) market