- The MP120D2 is a DC-controlled MP Series relay that switches 120 VAC at up to 2 A.
- The MP120D4 is a DC-controlled MP Series relay that switches 120 VAC at up to 4 A.MP Series power relays are designed for OEMs. They offer a minimum footprint to allow maximum relay density on a printed circuit board.Lots of information on choosing and using SSRs can be found in the SSR data sheet. Also see the Manufacturers’ part number cross-reference list.
This SSR carries a lifetime warranty.
|
MP120D2 |
MP120D4 |
Nominal AC Line Voltage |
120 |
120 |
Nominal Current Rating (Amps) |
2* |
4* |
1 cycle Surge (Amps) Peak |
20 |
85 |
Nominal Signal Input |
1000 |
1000 |
Signal Pick-up Voltage |
3VDC** |
3VDC** |
Signal Drop-out Voltage |
1 VDC |
1 VDC |
Peak Repetitive Voltage Maximum |
600 |
600 |
Maximum Output Voltage Drop |
1.6 volts |
1.6 volts |
Off-State Leakage mA Maximum*** |
5 mA |
5 mA |
Operating Voltage Range (Volts AC) |
12–140 |
12–140 |
I2t Rating t=8.3 (ms) |
2 |
30 |
Isolation Voltage |
4,000 VRMS |
4,000 VRMS |
θjc**** °C/Watt |
20 |
6.5 |
Dissipation Watts/Amp |
1.2 |
1.2 |
Rating (Motor Load) |
1 FLA at 120 VAC |
2.5 FLA at 240 VAC |
Notes:
* Ambient temperature will affect the current rating. For details, see the Thermal Ratings charts in the Solid State Relays Data Sheet (form 0859).
** = P Series 32 volts maximum.
*** Operating Frequency: 25 to 65 Hz (operates at 400 Hz with 6 times the offstate leakage).