Impeller Meters

Veris impeller meters are designed to be your most reliable and cost effect liquid metering solution. The most versatile meter in the category is the Small Diameter Impeller (SDI) series. It requires a small one inch opening and has minimal fluid obstruction for low pressure loss. Reliability is enhanced with a stainless steel impeller and standard with an ultra hard tungsten-carbide shaft and polyamide bearings. Besides frequency output the SDI series can provide analog and scaled pulse outputs and optionally contain an LCD flow display right on the meter. The Standard Impeller series requires a two inch opening. The forward swept impeller is Nylon and the standard shaft and bearings are tungsten-carbide and polyamide. Many other material options are available for those exotic applications. All impeller meters have frequency output but can be used with a Veris transmitter for a wide range of outputs and protocols.

Insert – Small Diameter Impeller

U001-0021 – Badger SDI0D1N10-0200. 1″ NPT, stainless shaft, PPS tip, direct insert for pipe 1-1/2″-10″, NEMA 4X housing, 4-20mA analog output, Viton O-ring, tungsten carbide impeller shaft. Must use U001-0020 programming cable.

A title

Image Box text

Insert – Standard Impeller Hot Tap

U001-0003 – Badger 225BR0005-1211. 2″ NPT, brass sleeve, gate valve, fits 3 inch to 40 inch pipe, frequency pulse output, EPDM O-ring, Tungston carbide shaft, Nylon impeller, UHMWPE bearing. Must use transmitter or monitor.

A title

Image Box text

Tee Meter, System BTU

U001-0154 – Badger 380207000-1202. 3/4″ NPT, cold and hot water, scaled pulse output, Modbus output and BACnet output.

A title

Image Box text

Insert – Standard Impeller

U001-0001 – Badger 220BR0005-1211. 2″ NPT, brass sleeve, fits 3 inch to 40 inch pipe, frequency pulse output, EPDM O-ring, Tungston carbide shaft, Nylon impeller, UHMWPE bearing. Must use transmitter or monitor.

A title

Image Box text

Tee Meter, Brass

U001-0008 – Badger 250BR0505-1211. 1/2″ NPT bronze tee, frequency pulse output, EPDM O-ring, Tungston carbide shaft, Nylon impeller, UHMWPE bearing. Must use transmitter or monitor.

A title

Image Box text

Moniors and Transmitters

Monitors and transmitters receive flow data from meters in frequency format. The data is converted to a useful format such as analog or one of many protocols. It can then be displayed on an easy-to-read LCD screen and/or sent to a building or process control system. Energy monitors and transmitters also accept dual temperature sensors and combine it with flow data to output thermal energy ( BTU) information. Veris monitors and transmitters accept signals from most meters and can display and transmit information in almost any communication format.

Local Display / BTU Monitor

U001-0023 – Badger 3000-10. Local display monitor, non-BTU, frequency pulse output, 4-20mA analog output, panel mount.

A title

Image Box text

Analog & BTU Transmitters

U001-0013 – Badger 310-00. Programmable, non-BTU, converts frequency input to 4-20mA analog output, loop voltage 9-35VDC.Must use U001-0020 programming kit.

A title

Image Box text

Ultrasonic

Veris offers a full line of transit time ultrasonic flow meters to satisfy a variety of applications. These products feature non-invasive technology designed to provide superb accuracy and response characteristics, making your job successful and cost effective.

Monitors (Flow and Energy)

The Veris line of monitors provide the means of collecting flow and energy data from transducers secured to a pipe. The monitors are available as flow or energy/flow versions. In addition the monitors can be specified as either AC or DC powered. All monitors require a transducer for a complete system.

A title

Image Box text

    Accessories

  • Programming and User Guide Kit.

  • Transducer Sonic Coupling Grease
  • Replacement insertion temperature sensor
  • Heat sink compound (thermal grease)
Transducers

Transducers provide flow signals to monitors by alternately transmitting and receiving a frequency modulated burst of sound energy. This energy is directed from the outside of the pipe to the liquid inside. Veris transducers are available to fit nearly any pipe material or size.

A title

Image Box text

Electromagnetic Meters

Standard

U020-0002 – M20HR020F15SACXX-MMXXVACXXGR. Badger Meter 2″ Magnetoflow Electromagnetic Flow Meter. Includes Hard Rubber Liner, Grounding Rings, AC Power and Meter Mounted Amp.

A title

Image Box text

Polymer

Flomec QSE05BSP09Q11A. FlowMeter, MagBTU, Norel, Disp, Pulse+Modbus, 1/2inch, BSPoutera

A title

Image Box text

Turbine Meters

FLO-02A12LM
02A12LM. 1″ Aluminum tee inline turbine meter,pulse output, BSPT, Liters, LCD display.

A title

Image Box text

Gas

B142-20L. Blancett Meter 2″ Gas Quicksert Impeller Flow Meter, Stainless Steel. Low flow rate version: 7-70 ACFM; 10-100 MCFD; 423-4230 MBH; 365 pulses per ACF (12900 pulses per m3).

A title

Image Box text

A title

Image Box text

A title

Image Box text